2036 Series

2 Way Solenoid Valves – General Purpose

Main Characteristic

Normally Closed
Pilot Operated diaphragm or piston
Brass Body
3/8, 1/2″, 3/8″ and 1″” NPT (BSP  upon request)
Coil: Encapsulated up to 356F with DIN Connectors or flying leads (upon request)
Wide Range of Pressure ratings, Buna N, Neoprene, EPDM, Teflon, and FKM seats
Nema4x and Explosion Proof

SPECIFICATION SHEET (pdf)

Applications:

Washing Machines.
Lubricated air, hot air, dry air, etc.
Oxygen and acetylene equipments.
Spaying. Irrigation.
Laundry and dry cleaning machines.
Air Dryers. Water Treatment plants.
Air Suspensions.

Options:

Explosion Proof
Weather Proof

Please select SEAT material by selecting the TAB
Connection SizesBody MaterialsOrifice Size InsFlow Factor CvMin. Diff. Pressure PsiMax. Diff. Pressure PsiModel #PriceBuyprice_hsort
0.512.932182036BA03T$108.20$121.80 108.2
0.514.232182036BA04T$108.20$121.80 108.2
0.636.43532182036BA06T$123.10$136.70 123.1
0.9810.534.51452036BA08T$242.40$256.00 242.4
Connection SizesBody MaterialsOrifice Size InsFlow Factor CvMin. Diff. Pressure PsiMax. Diff. Pressure PsiModel #PriceBuyprice_hsort
0.512.932182036BN03T
0.514.232182036BN04T
0.636.43532182036BN06T
0.9810.534.51452036BN08T
Connection SizesBody MaterialsOrifice Size InsFlow Factor CvMin. Diff. Pressure PsiMax. Diff. Pressure PsiModel #PriceBuyprice_hsort
0.512.932182036BE03T$112.50$126.10 112.5
0.514.232182036BE04T$112.50$126.10 112.5
0.636.43532182036BE06T$127.50$141.10 127.5
0.9810.534.51452036BE08T$246.80$260.40 246.8
Connection SizesBody MaterialsOrifice Size InsFlow Factor CvMin. Diff. Pressure PsiMax. Diff. Pressure PsiModel #PriceBuyprice_hsort
0.512.932182036BV03T$116.70$130.30 116.7
0.514.232182036BV04T$116.70$130.30 116.7
0.636.43532182036BV06T$131.70$145.30 131.7
0.9810.534.51452036BV08T$251.00$264.60 251
Connection SizesBody MaterialsOrifice Size InsFlow Factor CvMin. Diff. Pressure PsiMax. Diff. Pressure PsiModel #PriceBuyprice_hsort
0.512.932182036BT03T$148.70$162.30 148.7
0.514.232182036BT04T$148.70$162.30 148.7
0.636.43532182036BT06T$180.70$194.30 180.7
Options Prefix Suffix Examples
Explosion & Weather Proof Coil ZC ZC2036BA04T
BSP Connections no T 2036BA04T
Energized Coil Indicator Light please ask
INSTALLATION

Preferred mounting installation is horizontal pipe with coil up.
We recommend installing a strainer of <= 100 micron upstream to the valve.

Voltage Watts Resistance (ohms) Amps Inrush Amps Holding
12V/DC 6 0.5 0.5
24V/DC 6 0.25 0.25
110V/DC 6 0.05 0.05
24V/AC60 6 o.54 0.33
120V/AC60 6 0.11 0.06
240V/AC60 6 0.05 0.03

Other voltages available upon request.

GENERAL DIMENSIONS